Project Info
Huntsman A and O experienced a fire in the plant that melted process pipe and structural steel, destroying concrete support columns and beams in the pipe rack area, and table top slabs in the compressor area. The engineering group assessed the damage and Delta Structural Technology Inc. was brought in to survey the structural damage to the concrete. Delta provided additional testing to determine the exact nature of the heat damage to the concrete elements and performed tests on the imbedded steel anchor bolts. The concrete was chipped to sound concrete, destroyed steel rebar was replaced and bonding agents were applied, and patched with 10,000 psi polymerized repair mortar. Structural carbon fiber composite was applied to the underside of the beams to replace the lost steel reinforcing and composite e-glass was applied for shear strengthening and corrosion protection. The process was used in lieu of pre-stressed beam replacement due to significant decreased in project duration, obtained by the use of structural composites. The project was completed as scheduled and structural steel was installed immediately upon completion.The project was completed on time and on budget. |
|
| © 2009 Delta Structural Tech, Inc. | 3601 N Loop 336 W | Conroe, Texas 77304 |T: 281.821.3006 | F: 936.539.2118 | ||